312N TELEKOMUNIKACE a.s., www.2n.cz
®
Parameters
Input – define the digital input.
Valid values:
tamper – tamper switch
input1 – digital input 1
input2 – digital input 2
cr_input1 – digital input 1 on card reader
cr_input2 – digital input 2 on card reader.
There may be different lists of valid values for different 2N Helios IP
®
models; refer to the Available Digital Inputs and Outputs subsection.
Level – define the required digital input level. The parameter is optional.
Valid values:
0 – logic 0
1 – logic 1 (default value).
Example
The condition is met for an activated tamper switch (device not open):
Condition.InputState: Input1=tamper; Level=0
Condition.LogicalAnd
The block helps you create groups of conditions. The block is fulfilled if allLogicalAnd
the conditions in the defined group are met.
Parameters
Condition define the list of conditions to be met. Separate the conditions with
a comma.
Example
The condition is met if conditions 1, 2 and 3 are met at the same time:
Condition.LogicalAnd: Condition=1, 2, 3