2n M2M Solution 2N SmartCom - User Manual 1.9.0 Instrukcja Użytkownika Strona 124

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 149
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 123
1242N TELEKOMUNIKACE a.s., www.2n.cz
®
Caution
The message can be used for the and actions only.TCP SMS
You can also insert the following keys into the message parameter to show the value
currently measured on the input circuits or the current logic value of the conditions in
the SMS.
Key Description
$AIN1 Analogue input 1 value
$AIN2 Analogue input 2 value
$DIN1 Digital input 1 value
$DIN2 Digital input 2 value
$PUL1 Pulse input 1 value
$PUL2 Pulse input 2 value
$CNT1 Counter 1 value
$CNTx Counter x value (1-5)
$CON1 Condition 1 result value 1
$CONx Condition x result value (1-10)
Let us show you an example for illustration.
Suppose you want to enter a command into the terminal, which, when the limit value
80 on input 1 is exceeded, will send an SMS to number 123456789 including the
(the currently measured value).ALARM value is:
The AT command looks as follows:
AT^SCUDF="ADD","AIN1>80:SMS p[123456789] m[ALARM value is:$AIN1]"
The following SMS will be sent to the set number:
ALARM value is:87
Caution
Should you enter an invalid or incomplete key, the key will not be
included in the SMS sent.
Tip
Enter a special key $$ to display the $ character in the SMS as the
single $ character introduces other keys.